Selectivity (circuit breakers)
The coordination of overcurrent protection devices in an electrical network
Selectivity, also known as circuit breaker discrimination, is the coordination of overcurrent protection devices so that a fault in the installation is cleared by the protection device located immediately upstream of the fault. The purpose of selectivity is to minimize the impact of a failure on the network.
Nº Q108573915 ★★
Poco común · Saberes
Selectivity (circuit breakers)
The coordination of overcurrent protection devices in an electrical network
Selectivity, also known as circuit breaker discrimination, is the coordination of overcurrent protection devices so that a fault in the installation is cleared by the protection device located immediately upstream of the fault. The purpose of selectivity is to minimize the impact of a failure on the network.
Último precio
—
Precio mínimo
—
Mediana 7 d
—
Ventas 30 d
0
Rango 30 d
—
En circulación
0
Cotización
mediana
mín – máx
ventas
Sin ventas en el periodo
Ver tabla
| Fecha | mediana | Mín | Máx | ventas |
|---|
Historial de ventas
- Última venta
- —
- Media 30 d
- —
- Mínimo 30 d
- —
- Máximo 30 d
- —
- Ventas 7 d
- 0
- Ventas 30 d
- 0
Aún no hay ventas.
Ventas anónimas: sin comprador ni vendedor. Las cifras solo cuentan ventas entre jugadores.
En Wikipedia
Texto en inglés Aún no hay artículo en tu idioma: extracto en inglés.
Selectivity, also known as circuit breaker discrimination, is the coordination of overcurrent protection devices so that a fault in the installation is cleared by the protection device located immediately upstream of the fault. The purpose of selectivity is to minimize the impact of a failure on the network. Faults in an installation are, for example, overload and short circuit. There are four ways in which selectivity is achieved: Current selectivity: different breaking capacities Time selectivity: time delay before tripping of a breaker Energy based selectivity: analysis of the current waves Zone selective interlocking: communication between the breakers, forwarding a time delay instruction
Texto: Wikipedia en inglés, CC BY-SA 4.0. ·
Cartas cercanas
Conductividad (electrolítica)
Nº Q907564 ★★
Recloser
Electricity distribution networks circuit breakers
Nº Q618740 ★★
Circuit breaker design pattern
Behavioral design pattern in software development
Nº Q5121595 ★
Measurement category
IEC classification of live electric circuits
Nº Q1614348 ★★
Compatibilidad electromagnética
Nº Q747288 ★★★
Resistencia de contacto
Nº Q332329 ★